Trinone Safe-Tank Resilient System

Integrated automatic fire suppression and explosion prevention systems

for petrochemical storage tank farms

The complex includes nitrogen blanketing and emergency nitrogen inerting systems with simultaneous generation and delivery of 3% heavy air-mechanical foam to the fire zone. Simultaneous water cooling of adjacent tanks and a set of measures provided by the complex prevent the incident from developing into a cascade. Protected system components and a foam generation unit located outside the tank farm ensure the survivability of the equipment under various scenarios.

Subsystem 3 · operating principle · five stages

Single contract · coordinated by Trinone Group

How the fire suppression subsystem works

Five operating stages of the KB Foam Generation & Delivery System: standby, fire source detection, activation of the installation, foam supply and cooling, elimination of consequences. The points on the diagram open the subsystem equipment with the manufacturer’s specifications.

  1. Subsystem 1 · Normal operation Trinone N2 Blanketing Resilient System Continuous nitrogen blanket maintenance system
  2. Subsystem 2 · Emergency mode Trinone N2 Resilient System Emergency nitrogen inerting system
  3. Subsystem 3 · Final stage KB Foam 3% Resilient System 3% foam solution generation and delivery system
  4. Subsystem 4 · Pressure relief Trinone Venting Resilient System Emergency explosion pressure relief system
standby

System in standby mode

Minimal power consumption in automatic standby mode. The system can be started manually.

T + 0 s

Fire source detection

Thermal elements and sensors, including optical monitoring. The fire alarm signal is transmitted to the automated control center.

T + 10–15 s · start-up

Activation of the installation

On a signal from the controller, foam concentrate and water are supplied to the mixer; the foam and water flow is distributed in the specified directions.

T + 40 s · 100% mode

Foam supply and cooling

Heavy foam is supplied to the fire source while a water curtain is simultaneously created on adjacent tanks and installations.

after localization

Elimination of consequences

Minimal damage to objects and products covered with foam. Ease of equipment cleaning.

Above-ground hydrant

DN100 PN16 · KB Armatura

  • Outlets2 × DN80 + 1 × DN100
  • Protectionbreakaway flange pair
  • Drainautomatic, frost protection

Solenoid diaphragm valve

EMMV-P · DN 40–150 PN16 · KB Armatura

  • Pressureup to 12 bar · Δp ≥ 0.5 bar
  • Power supply220 V 50 Hz · 12/24/48 V DC
  • ProtectionIP54 · IP65 · Ex

Foam chamber

PS-4 600 · L4 / L8 / L12-16 · KB Armatura

  • Inlet / outletDN80–150 / DN125–250
  • Weight45–75 kg
  • Atmospheric sealglass plate

Foam deflector

PS 4-700 · SK 4 / 8 / 12 · KB Armatura

  • DN125 / 200 / 250
  • Versionsfixed and floating roof
  • Weight5–18 kg

Heavy foam generator

PS 4-500 · MS 4–16 · KB Armatura

  • Flow rate at 5 bar400–1600 l/min
  • Foam concentrate3%
  • Expansion ratio6.5–8

Tank roof sprinkler

PS 4-400 · KB Armatura

  • Spray pattern150° cone
  • Application rate≥ 0.6 l/min·m² of roof
  • Materialbrass · DN40 PN10 flange

Water curtain nozzle

PS 4-300 · G½″ · KB Armatura

  • Angle160°
  • Application rate≥ 1.2 l/min·m² of shell
  • Materialnickel-plated brass

Water spray nozzle

SMV 26 · Ød 7–11 · KB Armatura

  • Versions26.1 – 26.4
  • OrificeØd 7 / 9 / 10 / 11
  • Length39–44 mm
  1. standby

    System in standby mode

    Minimal power consumption in automatic standby mode. The system can be started manually.

  2. T + 0 s

    Fire source detection

    Thermal elements and sensors, including optical monitoring. The fire alarm signal is transmitted to the automated control center.

  3. T + 10–15 s · start-up

    Activation of the installation

    On a signal from the controller, foam concentrate and water are supplied to the mixer; the foam and water flow is distributed in the specified directions.

  4. T + 40 s · 100% mode

    Foam supply and cooling

    Heavy foam is supplied to the fire source while a water curtain is simultaneously created on adjacent tanks and installations.

  5. after localization

    Elimination of consequences

    Minimal damage to objects and products covered with foam. Ease of equipment cleaning.

Stages and design figures are taken from the system presentation. The points on the diagram are subsystem 3 equipment with the manufacturer’s specifications.

  • Trinone Group

    The Trinone Safe-Tank Resilient System complex: a single contract, coordination of the participants and documentation.

  • Institut Mihajlo Pupin

    Automated control center: controllers, SCADA and supervisory control of the system.

  • KB Armatura

    Equipment for the fire suppression subsystem: hydrants, foam chambers, foam generators, sprinklers, curtain nozzles, EMMV valves.

Subsystem 3 · KB Foam Generation & Delivery System

3% foam solution generation and delivery system

A modular unit with a high degree of factory readiness: the main foam concentrate supply system and a start-up and backup system in case of external power supply failure. Subsystem equipment: the heavy foam delivery chain is the foam chamber, deflector and foam generator; cooling is provided by roof sprinklers and the water curtain; start-up automation by solenoid valves; water supply by hydrants. Specifications are the manufacturer’s data.

  • DN100 · PN16above-ground hydrant
  • 400–2000 l/minfoam generators at 5–8 bar
  • ≥ 0.6 · 1.2 l/min·m²roof · shell cooling
  • DN 40–150EMMV valves · IP54/65 · Ex
DN100 PN16Above-ground hydrant

Above-ground hydrant

Outlets
2 × DN80 + 1 × DN100
Protection
breakaway flange pair
Drain
automatic, frost protection
EMMV-P · DN 40–150 PN16Solenoid diaphragm valve

Solenoid diaphragm valve

Pressure
up to 12 bar · Δp ≥ 0.5 bar
Power supply
220 V 50 Hz · 12/24/48 V DC
Protection
IP54 · IP65 · Ex
PS-4 600 · L4 / L8 / L12-16Foam chamber

Foam chamber

Inlet / outlet
DN80–150 / DN125–250
Weight
45–75 kg
Atmospheric seal
glass plate
PS 4-700 · SK 4 / 8 / 12Foam deflector

Foam deflector

DN
125 / 200 / 250
Versions
fixed and floating roof
Weight
5–18 kg
PS 4-500 · MS 4–16Heavy foam generator

Heavy foam generator

Flow rate at 5 bar
400–1600 l/min
Foam concentrate
3%
Expansion ratio
6.5–8
PS 4-400Tank roof sprinkler

Tank roof sprinkler

Spray pattern
150° cone
Application rate
≥ 0.6 l/min·m² of roof
Material
brass · DN40 PN10 flange
PS 4-300 · G½″Water curtain nozzle

Water curtain nozzle

Angle
160°
Application rate
≥ 1.2 l/min·m² of shell
Material
nickel-plated brass
SMV 26 · Ød 7–11Water spray nozzle

Water spray nozzle

Versions
26.1 – 26.4
Orifice
Ød 7 / 9 / 10 / 11
Length
39–44 mm

On site

Subsystem equipment on site

Tank farm with bunding
Tank farm with bunding
Above-ground hydrant on site
Above-ground hydrant on site
Tank shell cooling valve assembly
Tank shell cooling valve assembly
Insulated piping with valves and pressure gauges
Insulated piping with valves and pressure gauges
Tank farm and system piping
Tank farm and system piping
System piping on the tank roof
System piping on the tank roof

Application rates: at least 0.6 l/min per m² of roof and 1.2 l/min per m² of shell; 3% foam, expansion ratio 6.5–8, pressure upstream of the generator from 5 bar. Calculation for your tank farm →

Advantages

What the system provides

Design figures and advantages are taken from the system presentation.

  • 10–15 sfull system activation on a sensor signal
  • 40 sto reach 100% firefighting capacity and protection of adjacent tanks
  • 3%foam concentrate in the heavy air-mechanical foam solution

Start-up and control

  • Automatic and manual activation modes.
  • Full system activation within 10–15 seconds.
  • Transition to full 100% firefighting mode with protection of adjacent tanks within 40 seconds.

Facility safety

  • Prevention of explosion and tank destruction at the initial moment of ignition.
  • Preventive measures against fire spread to adjacent tanks.
  • No need for human presence in the ignition and explosion zone.

Operation

  • Reliability and ease of maintenance in standby mode.
  • Reduced water consumption for firefighting.
  • Minimal damage to anything covered with foam; foam is a harmless extinguishing agent.
  • Manufactured to the customer’s requirements and the geometry of the facility.

Questionnaire

System calculation for your tank farm

The questionnaire collects the input data for calculating the foam supply and cooling configuration. The reply comes from Trinone Group: equipment selection with the manufacturer, a single contract and documentation.

  • Tank geometry and volume, stored product
  • Water pressure and flow rate, site climate
  • Control and alarm requirements