Installation and operation
The regulator must operate on clean gas. A strainer is installed upstream of the regulator. Installation is horizontal; the standard flow direction is right to left.
GasTeh · G100 · Series 110
Type 113Small and pilot regulators
Reduces the inlet gas pressure and automatically maintains the specified outlet pressure. The required version is selected according to the process medium, flow rate, and inlet and outlet pressure ranges.
In the printed catalogpp. 12–13Manufacturer’s data
Manufacturer — GasTeh
The regulator must operate on clean gas. A strainer is installed upstream of the regulator. Installation is horizontal; the standard flow direction is right to left.
The series 110 high-pressure regulator provides a stable outlet pressure of accuracy class RG under varying inlet pressure and gas flow rate.
| Body | 40Kh steel |
|---|---|
| Seat | 12Kh18N10T steel |
| Seat plug | LS59-3 |
| Spring / setting spring | 50KhFA steel |
| Adjusting screw | 10kp steel |
| Diaphragm | Effbe |
| Piston | X5CrNi18-10 |
| Cap | plastic |
| G1 / G2 | G 1/4″ or G 1/2″ |
|---|---|
| A / B / C | 80 / 401 / 187 mm |
| p₂ range | 2-22 bar |
| RG / ZG | 5 / 10 |
Equipment selection
Tell us the medium, pressure, flow rate, temperature and connection. Trinone Group receives the inquiry: version selection with the manufacturer, one contract and the documentation.
QuestionnaireFill in onlineFill in by hand